chinese
japanese
homepage Hardness Testers Roughness Testers Vibration Meter Coating Thickness Gages Ultrasonic Thickness Gages Ultrasonic Flaw Detector
| |
Ultrasonic Flaw Detector
TUD210
 Ultrasonic Flaw Detector
TUD210
Special Feature:
-
Real-time multi-function system, stable, reliable and efficient
operation
-
The embedded software can be online updated
-
Big memory of 400 A graph and 40000 thickness value
-
Super Fast sampling capability, RF wave full display, minimum
display range 2.5mm
-
Wide & high bright EL display screen
-
Alternative switch between single probe and double probe
-
DAC automatically creation with standard test block
-
Li battery, continue working time up to 6 Hrs
-
USB and RS232 interface
-
3 offset adjustable DAC curve cater to various requirements of DAC
in all walks of life
-
400 independent flaw detection channel
-
High
speed sampling, radio frequency display with 80 MHz for sampling
Min. display range 2.5mm
Technical Specifications:
|
Test
Modes |
Pulse-echo and dual |
|
Pulser |
Spike excitation pulser |
|
Min. Range |
2.5mm (C=5920 m/s, steel) 0.1 inch (C=233 inch/ms) |
|
Max. Range |
5,000mm (C=5920 m/s, steel) 200 inch (C=233 inch/ms) |
|
Material Velocity |
1,000 to 9,999 m/s variable in steps of 1 m/s
40 to 390 inch/ms in steps of 0.1 inch/ms |
|
Vertical Linearity Error |
≤3% |
|
Dynamic Range |
≥32dB |
|
Horizontal Linearity Error |
≤0.2% |
|
Sensitivity Leavings |
≥50dB |
|
Pulse Displacement |
-20µs to +3400µs |
|
Probe Delay |
0-99.99µs, resolution 0.01 |
|
Gain |
0-110 dB variable in selectable steps of 0.2, 0.5, 1, 2, 6, 12
and 0.0 locked |
|
Damping |
50 ohms, 150 ohms and 400 ohms |
|
Rectification |
Full wave, positive half wave, negative half wave and RF |
|
Bandwidth |
Three selectable broadband (-3dB):
low 0.2-1MHz, Middle 0.5-4 MHz, High 1-10MHz |
|
Reject |
Linear, 0-80% of full screen, variable in steps of 1% |
|
Measurement Resolution |
Sound path: 0.1mm (display range<99.9mm) 1mm (display range
≥100mm) 0.01
inch (display
range <3.90 inch)
0.1 inch (display range ≥3.9 inch)Amplitude: 1% SH, highest echo in the Gate |
|
Display Screen and A-Scan |
Thin film electroluminescent display: 115mmX86mm (4.5
inchX34inch) 320X240 pixels, Zoom display, filled or outlined
display and A-scan freeze (gate movement in the frozen A-scan
impossible) |
|
Distance Readout |
Provide single echo or echo to echo thickness reading or sound
path, surface, and depth reading for angle beam testing with
either peak or flank detection |
|
Unit |
Metric/imperial |
|
Refracted angle |
Fixed setting of 0o, 30o, 45o,
60o, 70o, 90o or variable from
0o to 90o refracted angle in 1o
resolution |
|
Interface |
USB and RS232 bi-directional 9600 baud, 8 bits word length, no
parity, 1 stop bit |
|
Printer Driver |
TP UP-NH-S line thermal printer |
|
Power Supply |
Li batteries, continues working time approx. 6 Hrs or
Charger/Adapter DC output 9V/3A |
|
Low Battery Alarm |
On-screen warning of low battery |
|
AC Mains requirements |
85 to 264VAC/1.0A, 47 to 63Hz |
|
Charging Time |
5
Hrs Max. |
|
Operating Temperature |
0oC-40oC
(32F-104F) |
|
Storage Temperature |
-20oC-+60oC (-4F-140F) |
|
Dimension (D X W X H) |
53*184*230mm |
|
Weight |
1.4kg (3.1 lbs) with batteries |
|
Probe Connector |
LEMO |
|
Standard Delivery |
|
Optional Accessories |
|
Main Unit |
1 |
Ÿ
Standard Echo
Probe BH-50 |
|
Li Battery |
1 |
Ÿ
Angle-beam
Probe (5MHz-6x6K2) |
|
Neck strap |
1 |
Ÿ
Angle-beam
Probe (2.5MHz-13x13K2.5) |
|
Power supply adapter |
1 |
Ÿ
Straight-beam
Probe (2.5MHz-Ø14) |
|
Couplant |
1 |
Ÿ
Data View for
TUD201 (Software with PC cable |
|
Straight-beam probe
(2.5MHz-Ø20) |
1 |
Ÿ
TP UP-NH
Thermal line Printer (with power supply unit and 9 pin plug
cable) |
|
Angle-beam Probe
(5MHz-8x9K2) |
1 |
Ÿ
USB
communication cable |
|
Cable with LEMO
connector |
2 |
|
|
Hard shell case |
1 |
|
Ø3.2 Cross screwdriver |
1 |
|
Time Certificate |
1 |
|
Warranty Card |
1 |
|
Instruction Manual |
1 |
|
Carrying Case
|
1 |
|