Hardness Testers TH160
Metal Hardness Tester Model TH160
Features of TH160
Model TH160

- Metal hardness (Leeb) tester
- Conversion from HL to HRC, HRB, HB, HV and HS
- 6 impact devices available (D, DC, D + 15, C, G and DL)
- Automatic identification of impact devices
- User calibration capability
- 5 impact directions (0?? ??5?? ??0??
- Large 320??00 LCD with backlights displays data and histogram
- On-board memory holds 240-1000 groups of data
- Built-in Noise-free and ink-free printer
- Software to connect with PC
- Upper/lower limits setting and alarm
- Conversion from hardness to tensile strength
- Battery low indication and sound alarm
Specifications of TH160
| Hardness scale |
HL, HRC, HRB, HRA,HB, HV and HS |
| Tensile strength range (steel only) |
?? :374-2652 (MPa) |
| Impact device |
D (standard), DC/ D + 15 / C / G / DL (optional) |
| Accuracy |
Within ??.5 % (HLD=800) |
| Statistics function |
Average / Max. / Min. value calculation
Limits setting and alarm |
| Memory |
240-1000 groups of data |
Work piece radius (convex / concave)
?? |
Rmin=50mm (Rmin=10mm with support rings) |
| Min. depth of hardened surface |
0.2mm( Impact device C) |
| Power supply |
3.6V NiMH Rechargeable batteries |
Charging time
?? |
2 hours |
| Operating temperature |
0??to 40?? |
| Dimensions |
270x86x47mm |
| Weight |
About 675g |
Display range of TH160
- D probe is for standard use.
- DC probe is short and is convenient in small space.
- DL type is used in confined surfaces such as gear wheels.
- D+15 type is for measuring in grooves or recessed surfaces.
- C type is used on surface-hardened, coated, thin-walled or
impact sensitive components.
- G type is used on heavy and rough cast and forged work pieces.
| |
Impact Devices |
| D/DC/DL |
D+15 |
C |
G |
| Impacting energy |
11 Nmm |
11Nmm |
2.7Nmm |
90Nmm |
| Mass of impacting body |
5.5g/5.5g/7.3g |
7.8g |
3.0g |
20g |
| Hardness of spherical test tip |
1600HV |
1600HV |
1600HV |
1600HV |
| Diameter of spherical test tip |
3mm |
3mm |
3mm |
5mm |
| Material of spherical test tip |
Tungsten carbide |
| Diameter of impact device |
20 / 20 / 5mm |
20mm |
20mm |
30mm |
| Length of impact device |
147/86/202mm |
162mm |
141mm |
254mm |
| Weight of impact device |
75/50/87g |
80g |
75g |
250g |
| Max. hardness of sample |
940/940/950 HV |
940HV |
1000HV |
650HB |
| Average sample roughness |
Ra :2µm |
Ra :2µm |
Ra :0.4µm |
Ra :7µm |
| Min. weight of sample: |
|
|
|
|
|
In
compact shape |
5kg |
5kg |
1.5kg |
15kg |
|
On
solid support |
2kg |
2kg |
0.5kg |
5kg |
|
Coupled
on plate |
100g |
100g |
20g |
500g |
| Min. thickness of sample: |
|
|
|
|
|
coupled
|
3mm |
3mm |
1mm |
10mm |
|
Min.
thickness of layers |
0.8mm |
0.8mm |
0.2mm |
1.2mm |
| With 300HV |
Diameter |
0.54mm |
0.54mm |
0.38mm |
1.03mm |
| Depth |
24µm |
24µm |
12µm |
53µm |
| With 600HV |
Diameter |
0.54mm |
0.54mm |
0.32mm |
0.90mm |
| Depth |
17µm |
17µm |
8µm |
41µm |
| With 800 HV |
Diameter |
0.35mm |
0.35mm |
0.35mm |
-- |
| Depth |
10µm |
10µm |
7µm |
-- |
|